LMK807 Plastic Submersible Level Transmitter

LMK807 Plastic Submersible Level Transmitter
KL1 Vented Cable Termination Enclosure

Click Images to Enlarge

IP68 mid range pressure transmitter for measuring the level of highly contaminated and agressive liquid media with a body made from PVC or PVDF. Hydrostatic ranges from 4 mWC up to 100 mWC

Price | Del | PDF | Links

 

Product Parameters

Hydrostatic Level Ranges: 4 to 100 mWC

Accuracy: 0.25% FS BSL NLHR

Output Signal: 4 to 20mA, 2 wire current loop, optional SIL2

Electrical Connection: PVC, PUR or FEP cable with IP68 waterproof seal

Pressure Connection: Open face flush diaphram

Media Compatibility: PVC, PVDF or PVC-C sensor housing, FKM, EPDM or FFKM O ring seals and Ceramic Alumina Al2O3 diaphragm

Dimensions: 35 mm dia

Weight: 200 g

Special Features: Compatible with chemically corrosive fluids , no metal parts exposed to the liquid media

Special Options: Vented Aluminium cable termination box with over-voltage protection circuitry and/or internal PT 100 transmitter

 


Product Description 

The LMK 807 chemical resistant immersible level sensor includes a ceramic pressure sensing diaphragm which has a high corrosion resistant to most chemicals.

For waste-water applications the ceramic sensing element of the LMK-807 submersible level transmitter is semi-flush to prevent clogging and facilitate easy cleaning.

 


Delivery Time

3-4 weeks plus dispatch time

 


Related Products

Plastic immersible level transmitter with ranges below 4 mWC

More submersible hydrostatic level sensors

Flush diaphragm sensors for easy cleaning and decontamination

Liquid level transmitters with plastic wetted parts for corrosive chemicals

 


Download Product Information

LMK807 data sheet LMK807 data sheet

Cable Junction Box data sheet Cable Junction Box data sheet


Instant Quote

All prices are exclusive of any applicable VAT and delivery charges

£249.50

Hydrostatic Level Range:
Length and Type of Cable (metres):
Housing Material:
Seal Gasket Material:
Ceramic Diaphram Material:
Output Signal:
Vented Cable Junction Box:
Quantity:
Your Name:
Your Email:
Comments:

Home

Request Info | Ask a Question

Site Last Updated:  07/09/10

Save
Send |
Tools
Pressure Conversion



Converts to


Temperature Conversion



Converts to


IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Reference

Glossary - Find explanations for terminology used in specifying and using pressure instruments

Pressure Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Measuring Guide - Collection of guidance notes for sourcing, setting up and using pressure measurement equipment

News Articles - Archive of application notes, product releases and technical information

Specify

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Product Finder - Choose multiple product and application types to filter out a suitable product

Contact

Help:  Request Info

         Ask a Question

Articles
Subscribe

©2010 SensorsONE Ltd, All Rights Reserved.