DDS High Over-Pressure Differential Pressure Sensor

DDS High Over-Pressure Differential Pressure Sensor

Click Images to Enlarge

Differential pressure transmitter with high over-load capability for measuring low differential pressures from 8mb up to 6 bar differential.

FOR INFORMATION ONLY - THIS PRODUCT HAS BEEN DISCONTINUED

View current range of differential pressure instrumentation

 

PDF

 

Product Parameters 

Pressure Ranges: from 40 mb up to 6 bar differential

Overpressure: 100 bar >=400 mbar range on either port, 50 bar >=160 mbar range, 35 bar >= 40 mbar range  

Line Pressure: 100 bar max 

Accuracy: ±0.25% FS

Output Signal: Fully configurable 4 to 20 mA current or amplified voltage output available

Electrical Connection: Large DIN 43650 plug & socket, IP65 protection rating

Pressure Connection: 1/4 BSP female

Media Compatibility:  All stainless steel construction with Nitrile or Viton O ring seals suitable for use with liquids or gases

Special Features: Rangeable turndown of 5 to 1 for each base range range, bleed screws for venting pressure ports

Special Options: Non-linear output signals, square root, 3/2 and 5/2 type

 


Product Description 

The DDS differential pressure transducer can be used with either non-condensing clean gases or low viscosity liquids & condensing dirty gases with the silicone oil filled option.
The digital electronics can easily be configured to set-up a turndown range of up to 5 to 1, compound range, elevated zero, square root output for flow measurement, customer specified non-linear output, filter jump out or different RC time constants.

The DDS dp cell is designed for use in process control, industrial & HVAC applications.

 


Delivery Time

6-8 weeks plus dispatch time

 


Related Products

Low range differential pressure sensors

Other differential pressure instrumentation

Panel meters with alarms for connecting to differential pressure sensors

 


Download Product Information

DDS data sheet DDS data sheet


Request a Quote
Differential Pressure Range:
Output Signal:
End Flanges:
Diaphragm Material:
Flange Seals:
Output Signal Special Options:
Digital Filtering Response Time:
Output Signal Filtering Jump Out:
Electrical Connection:
Length of Cable (metres) if required:
Calibration report:
Quantity:
Name:
Email:
Country:
Comments:

Site Last Updated:  21/05/12

Save
Tools
Pressure Conversion



Converts to



Temperature Conversion



Converts to



IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Reference

Glossary - Find explanations for terminology used in specifying and using pressure instruments

Pressure Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Measuring Guide - Collection of guidance notes for sourcing, setting up and using pressure measurement equipment

News Articles - Archive of application notes, product releases and technical information

Answers - Search for questions already answered or submit a new question about a pressure measurement topic or product

Specify

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Product Finder - Choose multiple product and application types to filter out a suitable product

Articles


 

©2012 SensorsONE Ltd, all rights reserved.