33X High Accuracy Digital Output Pressure Sensor

33X high Accuracy Digital Output Pressure Sensor
Reading and logging software for analysis and reports Configuration software for managing pressure sensor settings

Click Images to Enlarge

High precision pressure transducer with an accuracy of 0.05% full scale including temperature errors over +10 to +40 deg C. Available in pressure ranges from 1 to 1000 bar gauge or absolute with a RS485 digital interface plus an optional USB or RS232 converter cable for connecting to a desktop or laptop PC.

Quote | PDF

 

Product Parameters

Pressure Ranges: from 1 up to 1000 bar (15 -15000 psi) gauge, absolute or sealed gauge

Accuracy: 0.05%FS over +10 to +40 degC and 0.1%FS over -10 to +80 degC

Output Signal: USB, RS232 or RS485 digital interface for pressure, temperature and programming

Electrical Connections: IP 65 or 68 Cable or Binder connector for sensor, USB male or RS232 9 pin D sub plug for PC interface

Pressure Connectors: 1/4 BSP male

Weight: 140g

Special Features: Connect up to 16 digital pressure sensors on one serial bus connection, measure/log pressure and temperature simultaneously

Special Options: All Hastelloy C276 wetted parts for higher corrosion resistance

 


Product Description

The 33X digital pressure sensor incorporates silicon strain gauge sensing technology and digital characterisation techniques to produce a highly accurate pressure sensor over a wide temperature range.

The optional USB or RS232 converter cable enables the 33X digital pressure sensor to be used with the prog30 instrument programming software and the read30 data collection software.  The live pressure reading can be measured or a data logging procedure can be set up for recording pressure data at set intervals.  All data can be displayed in the form of graphs and printed out if necessary.

The 33X digital pressure sensor also incorporates a temperature sensor which is located very close to the diaphragm in contact with the media.  This temperature sensor is used to digitally correct the pressure sensor at different temperatures and it is also provided as an output signal via the RS485 interface.

 


Related Products

Digital output pressure sensor for measuring below 300 mbar

Differential pressure sensors with digital outputs

Other pressure instrumentation for connecting to a computer

 


Download Product Information

33X data sheet 33X data sheet


Request a Quote
Pressure Range:
Electrical Connection:
Length of Cable (metres) if required:
Digital Communication:
Compensated Temperature Range:
Wetted Parts:
Quantity:
Name:
Email:
Country:
Comments:

Site Last Updated:  21/05/12

Save
Tools
Pressure Conversion



Converts to



Temperature Conversion



Converts to



IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Reference

Glossary - Find explanations for terminology used in specifying and using pressure instruments

Pressure Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Measuring Guide - Collection of guidance notes for sourcing, setting up and using pressure measurement equipment

News Articles - Archive of application notes, product releases and technical information

Answers - Search for questions already answered or submit a new question about a pressure measurement topic or product

Specify

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Product Finder - Choose multiple product and application types to filter out a suitable product

Articles


 

©2012 SensorsONE Ltd, all rights reserved.