DMP331 Low Compound Range Pressure Transmitter

DMP331 with process style field housing option
DMP331 with semi-flush diaphragm option

Click Images to Enlarge

Combined negative gauge and positive gauge pressure sensor for measuring pressures above and below atmospheric pressure from ±40mbar up to ±1 bar gauge

Quote | PDF | Spec | Links 

The DMP 331 compound range pressure transducer has a semiconductor strain gauge sensing element with a vent to atmospheric pressure on the reverse side of the silicon diaphragm which provides a gauge pressure reference.  The Silicon element is protected from the process media by sealing it inside an oil filled capsule with a convoluted isolation membrane to facilitate the transfer of pressure to the sensing element.

The DMP-331 bi-directional pressure sensor has a variety of configurations with all welded wetted parts, semi-flush diaphragm, process style electronics housing and IP68 buccaneer electrical connector.

 

Technical Summary 

Pressure Range: ±40 mbg up to ±1000mb g (±0.6 psi to ±15 psi)

Accuracy: 0.175% > 0.4 bar, 0.25% <= 0.4 bar as standard with options for 0.125%, 0.1% and 0.05% FS BSL NLHR

Output Signal: 4-20mA (2 wire), 0-20mA (3 wire) current or 0-10V voltage

Electrical Connections: Field housing with M16 cable entry, DIN43650, binder, buccaneer or M12 sockets plus integral cable glands with ingress protection to IP67 or IP68

Pressure Connectors: G1/4, G1/2, 1/4 or 1/2 inch NPT male thread plus G1/2 flush diaphragm (EN837 only), open pressure port design and M20 x 1.5 male

Media Compatibility: Stainless steel 316 Ti pressure port, stainless steel 316L diaphragm with all welded, FKM or EPDM O ring internal seal

Special Features: low compound pressure ranges


Related Products

More compound range pressure transmitters which combine measurement of positive and negative gauge pressure

Panel meters for displaying positive and negative gauge pressure

Hand pumps for testing compound pressure ranges by switching between vacuum and pressure operation


Resources

What is a compund pressure range?

Reference guide for pressure sensor technical terms 

Convert a compound range into different pressure units


Download Product Information

DMP331 data sheet DMP331 data sheet

DMP331 operating manual DMP331 operating manual


Request a Quote
Pressure Range:
Output Signal:
Accuracy:
Electrical Connection:
Length of Cable (metres) if required:
Pressure Connection:
Seals:
Compensated Temperature Range:
Quantity:
Your Name:
Your Email:
Comments:

Home > Your Application > Pressure Testing > Leak Testing

Request Info | Ask a Question | Call Request

Site Last Updated:  04/07/08

Tools
Pressure Conversion


Equals

Temperature Conversion


Equals

IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Resources

Pressure Measurement Glossary - Find explanations of terminology used for specifying and using pressure instruments

Pressure Unit Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Contact

Tel: +44 (0)1780 721569

Fax: +44 (0)1780 721586

Email: Enquiries

Help:  Request Info

         Ask a Question

         Call Request

News
RSS News Feed
RSS

©2008 SensorsONE Ltd, All Rights Reserved.

Powered by interdesigns