Select a pressure sensor or instrument with a pressure range between 100 and 1000 Bar (1500 to 15000 psi).
High precision pressure transducer with an accuracy of 0.05% full scale including temperature errors over +10 to +40 deg C. Available in pressure ranges from 1 to 1000 bar gauge or absolute with a RS485 digital interface plus an optional USB or RS232 converter cable for connecting to a desktop or laptop PC.
Highly accurate digitally compensated pressure transducer with G1/2 male flush pressure port. Designed for use on viscous media or where a flush face is required for easier cleaning when used with food, drink or hazardous substances such as Oxygen. Select pressure ranges as low as 1 bar or as high as 1000 bar. Standard digital output is RS485 which can be converted to RS232 or USB via optional converter cables.
Dual analogue output signal transmitter for simultaneous measurement of media pressure and temperature. Pressure ranges from 100 mbar up to 1000 bar and temperature measuring range from -25 to 100 DegC. To ensure good thermal contact with the media the temperature is measured just behind a flush diaphragm which has sufficient surface area to ensure minimal losses in media temperature at point of measurement.
Battery powered pressure gauge with all welded wetted parts with exposed diaphragm for measuring high range pressures of viscous/pasty fluids or media which requires the use of hygienic equipment. Measure pressure ranges from 0-60 bar (900 psi) to 0-400 bar (6000 psi) gauge or absolute. Supplied with a G1/2 or a G1 male flush diaphragm process fitting for thread mounting.
Robust industrial self powered logger for recording up to 130,000 pressure values with a minimum logging interval time of 2 seconds. Select a pressure from 0 to 100 mbar to as high as 0 to 1000 bar gauge or absolute.
Stainless steel 316L wetted parts pressure sensor for high pressure ranges from 60 bar (900 psi) up to 600 bar (9000 psi). Used on applications such as hydraulic test benches, presses, injection moulding machines, hydraulic actuation and vehicle hydraulic systems. Accurate to 0.35% FS with options for 0.25% or 0.1% FS. Good long term stability of 0.1% FS over a period of 1 year.
High performance transducer with adjustable scaling for modifying the pressure range for different applications. Ranges from 0-60 bar up to 0-600 bar gauge or absolute. The output signal is accurate to 0.1% of base range or 0.5% with a 10:1 turn-down, and a 14 bit analogue to digital conversion provides a high resolution amplified output. Optional software and interface kit is available for re-ranging the output signal.
Versatile low price pressure transducer with a wide selection of electrical and mechanical options to enable the customisation of the sensor to suit most industrial, automation and OEM design installations. A dry cell ceramic strain gauge sensing diaphragm provides a high corrosion resistance to many types of harsh chemical media commonly found in automated industrial processes and machinery monitoring applications.
Combined digital manometer and pressure data logging instrument for recording pressures and temperatures which can store up to 57,000 readings in the non-volatile memory with a battery life of up to 5 years.
Battery powered digital gauge with an accuracy of 0.2% full scale in pressure ranges from -1 to 3 bar up to 1000 bar. The LEO 1 digital pressure gauge features 6 pressure units, rotatable display, zero tare & peak hold display functions and optional ATEX approval for intrinsic safety.
LCD digital pressure gauge powered externally by a 2 wire series 4-20mA current loop or a digital interface. Use as a pressure transmitter or a digital output pressure sensor with a local readout display. Accurate to 0.2% FS the LEO3 is available in a sleection of pressure ranges from -1 to 3 bar up to 1000 bar (-15 to 45 psi up to 15,000 psi).
High precision digital pressure gauge with an accuracy of 0.05% full scale in pressure ranges from -1 to 2 bar up to 1000 bar. The LEX 1 high accuracy digital pressure gauge features 6 pressure units, rotatable display, zero tare & peak hold display functions and optional ATEX approval for instrinsic safety.
Passive compensated pressure transducer with a four arm semiconductor Wheatstone bridge circuit which produces a 100 millivolt with a 10 volt excitation. Pressure ranges from 0-100mbar up to 0-1000bar gauge or absolute. The silicon sensing chip is totally isolated from the media by an oil filled stainless steel 316L capsule with isolation membrane. This sensor is ideally suited for high frequency response applications since the output is only limited by the natural response of the silicon sensing capsule.
Piezo-resistive pressure sensor with a millivolt output direct from a four arm wheatstone bridge strain gauge circuit in pressure ranges from 10 up to 1000 bar gauge.
Site Last Updated: 21/05/12
Glossary - Find explanations for terminology used in specifying and using pressure instruments
Pressure Conversion - Look up conversion factors or select a conversion table for a particular pressure unit
Pressure Measuring Guide - Collection of guidance notes for sourcing, setting up and using pressure measurement equipment
News Articles - Archive of application notes, product releases and technical information
Answers - Search for questions already answered or submit a new question about a pressure measurement topic or product
Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry
Product Finder - Choose multiple product and application types to filter out a suitable product
©2012 SensorsONE Ltd, all rights reserved.