P200IS Hazardous Area Digital Manometer

P200IS ATEX approved Digital Manometer

Click Images to Enlarge

Digital pressure manometer for hazardous areas with pressure ranges from 100 mbar up to 2000 mbar differential or gauge plus 2000 mbar absolute. The reading accuracy is 0.1% reading plus 0.1% full scale + 1 digit over 20 to 30°C.

Quote | PDF

 

Product Parameters

Pressure Ranges: 0-100 mbar up to 0-2 bar differential & 0-2000 mbar abs

Accuracy: ±0.1% rdg ± 0.1% fs ±1 digit over +20 to +30 degC

Power Supply: 1 x 9V PP3 Zinc Chloride battery, 100 hours typical battery life, (not included)

Display: 3 1/2 digit LCD

Environmental Protection: IP64

Media Compatibility: Positive port will accept non-corrosive, non-ionic liquids & gases.  Negative port will accept non-condensing gases

Dimensions: 140x70x26mm (5.5x2.8x1.0 inches)

Weight: 250g (8.8oz)

Special Options: Calibraton handpumps, calibration certificate

 


Product Description 

The P200 IS ATEX approved digital manometer can be used in hazardous areas which may contain flammable and explosive gases requiring certification up to EEx ia IIC T4.  For outdoor use the P200-IS hazardous area digital manometer has a robust weatherproof case which is sealed to IP64 protection rating.  The 31/2 LCD digit display is powered by a 9V PP3 zinc chloride battery and the typical lifetime is 100 hours.  There is also a low battery indicator.

 


Delivery Time

2-3 weeks plus dispatch time

add 2 weeks with UKAS calibration

 


Related Products

IS approved digital pressure gauges for mounting on process tapping points 

More portable digital manometers for pressure testing

Pressure recorders for use in hazardous areas

Field pressure calibators with ATEX approval

 


Download Product Information

P200IS data sheet P200IS data sheet


Request a Quote
Pressure Range:
Carry case:
Length of Nylon tubing if required (metres):
T piece for Nylon tubing:
Calibration certificate:
Quantity:
Name:
Email:
Country:
Comments:

Site Last Updated:  08/02/12

Save
Tools
Pressure Conversion



Converts to



Temperature Conversion



Converts to



IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Reference

Glossary - Find explanations for terminology used in specifying and using pressure instruments

Pressure Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Measuring Guide - Collection of guidance notes for sourcing, setting up and using pressure measurement equipment

News Articles - Archive of application notes, product releases and technical information

Answers - Search for questions already answered or submit a new question about a pressure measurement topic or product

Specify

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Product Finder - Choose multiple product and application types to filter out a suitable product

Articles
 

©2012 SensorsONE Ltd, all rights reserved.