DPS Low Differential Pressure Transmitter

DPS Low Differential Pressure Transmitter

Click Images to Enlarge

Ultra low differential pressure sensor for HVAC applications with 4-20mA current loop or amplified voltage output signal in pressure ranges from 0.1 mb up to 1 bar differential.

Quote | PDF | Spec | Links

DPS very low differential pressure transducer is an affordable option for measuring the differential pressure of airflow on heating, cooling, ventilation & air conditioning (HVAC) systems in buildings, laboratories, cleanrooms & factories.

The DPS ultra low differential pressure transmitter can also be used for measuring filter condition and ensuring a differential pressure between two rooms.

For overpressure conditions where there is the risk of a pressure up to 2 bar maximum being applied to either pressure port there is an optional automatic overpressure protection feature that can be specified which uses high frequency valves to isolate the DPS differential air pressure sensor from the system and vent both ports to atmospheric pressure.  After a few seconds the valves will re-open very quickly and if an overpressure condition still exists they will quickly close again to protect the sensor.

 

Technical Summary 

Pressure Ranges: 10 Pa to 100 kPa differential

Static Line Pressure: 1 bar gauge max 

Accuracy: 1% FS non-linearity with optional 0.5 or 0.2% FS, 0.1% FS hysteresis

Output Signals: 0-10V, 4-20mA or 0-20mA

Electrical Connection: 2 enclosure cable glands M12 x1.5 with 5 internal screw terminals

Pressure Connections: 6.6mm dia x 11mm barbed push on connections for 6mm dia flexible tubing or clamp ring tube fitting 1/8 inch MS

Environmental Protection: IP54

Media Compatibility: Non aggressive gases, Ni, Al, CuBe, PU, silicon rubber

Weight: 300 - 400g

Sensor Supply Voltage: 19-31Vdc, 12-32Vdc (2 wire only), 24Vdc isolated, 24Vac & 230Vac

Special Options: Integrated LCD display, Alarm relay outputs, auto-zero tare and up to 2 bar overpressure auto protection.


Related Products

Differential pressure sensors for use with liquids

Micromanometers for low pressure testing

Low range pressure calibrator


Resources 

Pressure transmitter glossary of terms

Conversion table for low range pressure units


Download Product Information

DPS data sheet DPS data sheet

DPS operating manual DPS operating manual


Request a Quote
Pressure Range:
Output Signal:
Square root extraction output (not with 2 wire 4-20mA or contact relays):
LCD display (3 1/2 digit):
Limit contacts (not with 2 wire 4-20mA or square root output):
Autozero & overpressure protected to 2 bar diff (not with 2 wire 4-20mA):
Overpressure protection:
Supply Voltage:
Linearity:
Pressure Connection:
Quantity:
Your Name:
Your Email:
Comments:

Home > Your Application > Air Pressure > Air Pressure Transmitters - Current Output

Request Info | Ask a Question

Site Last Updated:  12/10/08

Tools
Pressure Conversion


Equals

Temperature Conversion


Equals

IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Resources

Pressure Measurement Glossary - Find explanations of terminology used for specifying and using pressure instruments

Pressure Unit Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Contact

Tel: +44 (0)1780 721569

Fax: +44 (0)1780 721586

Email: Enquiries

Help:  Request Info

         Ask a Question

News
RSS News Feed
RSS

©2008 SensorsONE Ltd, All Rights Reserved.