LMK351 High Overpressure Flush Level Transmitter


LMK351 Flush Ceramic Level Transmitter

Click Images to Enlarge

Flush capacitive ceramic pressure sensor for measuring corrosive and viscous liquid level from levels 0.4 metres of water up to 100 mH2O. This screw-in fluid level transmitter features high overload rating up to 50x and options for all plastic wetted parts.

Quote | PDF | Spec | Links

The LMK351 high abrasion resistant level sensor incorporates ceramic capacitance diaphragm technology which exhibits high accuracy and over-pressure at low liquid levels.

The capacitive aluminium oxide (Al2O3) ceramic sensing diaphragm of the LMK351 chemical level sensor is highly resistant to abrasive materials and corrosive chemicals such as acids and alkalines. For chemicals that are not compatible with stainless steel 316Ti there are options for PVC or PVDF screw-in fittings.

For installations where frequent external washdown of storage tanks and equipment is required an IP68 buccaneer electrical connector can be selected for the LMK351 aggressive media level transmitter to make it waterproof.

A liquid level range from 1.3 up to 328 feet of water column can be specified for the LMK351 low range chemical level sensor with measurement accuracy of ±0.175 or 0.125% full scale.

For hazardous areas with volatile gases or dust present the LMK351 chemical level sensor has optional ATEX approved intrinsically safe electronics for use with IS barriers.

 

Technical Summary

Pressure Ranges: from 400 mmH2O up to 100 mH2O WC

Accuracy: 0.175% FS BSL NLHR or optional improved to 0.125% FS

Output Signals: 4-20mA or 0-10V dc

Electrical Connections: DIN plug, M12 Binder or waterproof buccaneer connectors plus integral cable options with IP67 or IP68 protection 

Internal Wetted Seals: FKM, EPDM or FFKM

Pressure Connector: G1 1/2 DIN3852 male thread with flush diaphragm

Special Features: Low range and high overpressure, robust and chemically inert diaphragm

Special Options: PVC or PVDF housing for aggressive chemicals, ATEX approved for intrinsic safety


Related Products

Flush diaphragm presssure and hydrostatic level sensors

Ceramic diaphragm liquid level sensors

Plastic body level sensors

Intrinsically safe hydrostatic pressure sensors


Resources

Find definitions for technical terms used to specifiy pressure sensors  

mWG conversion table for hydrostatic pressure units


Download Product Information

LMK351 data sheet LMK351 data sheet

LMK351 operating manual LMK351 operating manual

Hazardous Area installation manual Hazardous Area installation manual


Request a Quote
Pressure Range:
Output Signal:
Electrical Connection:
Length of Cable (metres) if required:
O-Ring Material :
Pressure Connection Material:
ATEX IS Approval (4-20mA output only):
Ceramic Diaphragm Material:
Accuracy:
Quantity:
Your Name:
Your Email:
Comments:

Home > Your Application > Level Measurement > Plastic Level Sensors

Request Info | Ask a Question | Call Request

Site Last Updated:  17/05/08

Tools
Pressure Conversion


Equals

Temperature Conversion


Equals

IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Resources

Pressure Measurement Glossary - Find explanations of terminology used for specifying and using pressure instruments

Pressure Unit Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Contact

Tel: +44 (0)1780 721569

Fax: +44 (0)1780 721586

Email: Enquiries

Help:  Request Info

         Ask a Question

         Call Request

News
RSS News Feed
RSS

©2008 SensorsONE Ltd, All Rights Reserved.