enquiries@sensorsone.co.uk
Differenital pressure transducers with amplified volts output for measuring the dp of liquids and gases.
Differential air pressure sensor with a 10 volt or a 4-20mA output for building ventilation applications. Designed for incorporating into a building HVAC management system to monitor and control the distribution of warm or cool air through ventilation ducts. Pressure ranges from 0 to 1 mbar up to 0 to 1000 mbar differential.
Wet wet differential pressure sensor with a high overpressure rating on both positive and negative side port for protection against accidental diaphragm damage. The DMD 331 has 6 nominal pressure range from 0-0.2 bar up to 0-16 bar differential and each range has a choice of sub-ranges which can be selected depending on the required level of overpressure rating. The differential pressure signals can be transmitted as linear 4-20mA or 0-10Vdc analog output.
High precision pressure transmitter for measuring very low vented gauge reference or differential air pressures. Each presssure range can be adjusted to scale the 4-20mA or 0-10 volt output signal from 10 to 100% of the base range. Designed for measuring pressures across air filters, ventilation fans and valves on HVAC and pneumatic systems.
Differential pressure transmitter with high over-load capability for measuring low differential pressures from 8mb up to 6 bar differential.
Small size dp sensor for measuring differential air pressure on HVAC, compress air and pneumatic control systems. The DMD341 is used to measure pressures in the range of 0-6 mbar up to 0-1000 mbar differential. An output signal of 4-20mA, 0-20mA or 0-10Vdc can be chosen to suit the signal conditioning of most air handling management systems.
Ultra low differential pressure sensor for HVAC applications with 4-20mA current loop or amplified voltage output signal in pressure ranges from 0.1 mb up to 1 bar differential.
Low range differential pressure sensor with rangeable 4-20mA current loop or amplified voltage output signal in pressure ranges from 1.6mb up to 6 bar differential
High precision compact wet wet differential pressure transmitter with digitally corrected 4-20mA current loop or amplified voltage output signal in pressure ranges from 1 up to 30 bar differential.
High pressure differential sensor that has high over-pressure with 4-20mA current loop or amplified voltage output in scaleable differential ranges from 3 bar up to 300 bar differential
tel: +44 (0)844 800 9440
©2013 SensorsONE Ltd, all rights reserved.