Home > Your Application > Low Ranges > Differential Sensors - Low Pressure
Low differential pressure range sensors for measuring low level dp pressures.
Differential air pressure sensor with a 10 volt or a 4-20mA output for building ventilation applications. Designed for incorporating into a building HVAC management system to monitor and control the distribution of warm or cool air through ventilation ducts. Pressure ranges from 0 to 1 mbar up to 0 to 1000 mbar differential.
High precision pressure transmitter for measuring very low vented gauge reference or differential air pressures. Each presssure range can be adjusted to scale the 4-20mA or 0-10 volt output signal from 10 to 100% of the base range. Designed for measuring pressures across air filters, ventilation fans and valves on HVAC and pneumatic systems.
Low pressure sensor with a USB, RS232 or RS485 digital output interface for measuring low range gauge or differential pressures. A choice of three pressure ranges are available: 10, 20, 30, 50, 100, 200 or 300 mbar, each with an accuracy of 0.1% full scale over a temperature of -20 to +80 DegC
Differential pressure transmitter with high over-load capability for measuring low differential pressures from 8mb up to 6 bar differential.
Small size dp sensor for measuring differential air pressure on HVAC, compress air and pneumatic control systems. The DMD341 is used to measure pressures in the range of 0-6 mbar up to 0-1000 mbar differential. An output signal of 4-20mA, 0-20mA or 0-10Vdc can be chosen to suit the signal conditioning of most air handling management systems.
Ultra low differential pressure sensor for HVAC applications with 4-20mA current loop or amplified voltage output signal in pressure ranges from 0.1 mb up to 1 bar differential.
Low range differential pressure sensor with rangeable 4-20mA current loop or amplified voltage output signal in pressure ranges from 1.6mb up to 6 bar differential
Rangeable DP Cell current loop process transmitter for monitoring differential pressures in a heavy duty process plant environment. The XMD has a standard process configuration with kidney flange mounting arrangement and large accessible electronic housing. Other features include ATEX intrinsic safety or flameproof, linear or square root extraction 4-20mA output, HART communications, 10 to 1 turndown ranging, LCD readout and 130 bar overpressure protection on one side.
Home > Your Application > Low Ranges > Differential Sensors - Low Pressure Need help? Ask a question | Send email tel: +44 (0)844 800 9440
tel: +44 (0)844 800 9440
Pressure Conversion bar psi mbar N/m² Pa hPa kPa MPa kg/cm² mmH2O 4°C cmH2O 4°C mH2O 4°C inH2O 4°C ftH2O 4°C mmHg 0°C cmHg 0°C inHg 0°C Torr mTorr atm at dyn/cm² oz/in² µHg 0°C tsi (uk, long) tsi (usa, short) tsf (usa, short) psf g/cm² Converts to bar psi mbar N/m² Pa hPa kPa MPa kg/cm² mmH2O 4°C cmH2O 4°C mH2O 4°C inH2O 4°C ftH2O 4°C mmHg 0°C cmHg 0°C inHg 0°C Torr mTorr atm at dyn/cm² oz/in² µHg 0°C tsi (uk, long) tsi (usa, short) tsf (usa, short) psf g/cm²
IP Ratings Explained I P 0 1 2 3 4 5 6 0 1 2 3 4 5 6 7 8 9K First Digit (Solids) No protection Second Digit (Liquids) No protection
Temperature Conversion Celsius Kelvin Fahrenheit Converts to Celsius Kelvin Fahrenheit
©2013 SensorsONE Ltd, all rights reserved.