35X Flush Diaphragm Digital Output Pressure Sensor

35X Flush diaphragm digital pressure sensor
Analyse recorded pressure readings Change settings and configuration of pressure sensor

Click Images to Enlarge

Highly accurate digitally compensated pressure transducer with G1/2 male flush pressure port. Designed for use on viscous media or where a flush face is required for easier cleaning when used with food, drink or hazardous substances such as Oxygen. Select pressure ranges as low as 1 bar or as high as 1000 bar. Standard digital output is RS485 which can be converted to RS232 or USB via optional converter cables.

Quote | PDF | Spec | Links

The 35X flush diaphragm digital output pressure sensor is accurate to 0.05% of full scale over a 10 to 40degC temperature range or can be widened to 0.1% over -10 to +80 degC.  The temperature signal used to compensate the pressure reading is also provided as a separate digital output.

This pressure sensor includes a highly repeatable and stable silicon chip sensing element which is housed inside a stainless steel £16L oil filled capsule from which the output signal is processed by the microprocessor electronics and a 16 bit analogue to digital converter to produce an RS485 output. 

The flush diaphragm can be back filled with different oils so that if the diaphragm is damaged it will be safe for the oil to mix wih the process media without increasing the volatility of the media or introduce any toxic material.

 

Technical Summary

Pressure Ranges: from 1 to 1000 bar (15 to 15000 psi) gauge, absolute or sealed gauge

Accuracy: 0.05% FS over +10 to +40 degC and 0.1% FS over -10 to +80 degC

Output Signal: RS485, USB or RS232 digital connection for pressure, temperature and programming

Electrical Connections: IP65 or IP68 cable or Binder 723 series connector for sensor, USB male or RS232 9 pin D sub plug for computer interface

Pressure Connectors: G1/2 male flush (1/2 inch BSP)

Weight: 160g

Special Features: Flush face pressure port.  Connect up to 16 digital pressure transducers on one RS485 bus connection, measure/log pressure and temperature simultaneously

Special Options: Galden D20 or Fombin M100 oil-fills for Oxygen compatibility, Olive oil-fill for food and beverage applications and Diffelen oil-fill for high vacuum use.  All Hastelloy C276 wetted parts for higher corrosion resistance.


Related Products

Other digital pressure transducers

Pressure instrumentation for connecting to a computer

Flush diaphragm pressure transducers and transmitters

Sanitary pressure sensors for use with food or pharmaceuticals

Oxygen service pressure transducers and transmitters


Resources

Technical terms guide to pressure sensors

Converting pressure into different engineering units


Download Product Information

35X data sheet 35X data sheet

Data Cable data sheet Data Cable data sheet

PC Software operating manual PC Software operating manual

Communications Protocol operating manual Communications Protocol operating manual


Request a Quote
Pressure Range:
Electrical Connection:
Length of Sensor Cable (metres):
Digital Communication:
Compensated Temperature Range:
Capsule Oilfill:
Wetted Parts:
Quantity:
Your Name:
Your Email:
Comments:

Home > Your Application > High Accuracy > Highly Accurate Digital Pressure Sensors

Request Info | Ask a Question

Site Last Updated:  20/11/08

Tools
Pressure Conversion


Equals

Temperature Conversion


Equals

IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Resources

Pressure Measurement Glossary - Find explanations of terminology used for specifying and using pressure instruments

Pressure Unit Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Contact

Help:  Request Info

         Ask a Question

News
RSS News Feed
RSS

©2008 SensorsONE Ltd, All Rights Reserved.