DS200 Combined Pressure Switch, Gauge and Sensor

DS200 Combined Pressure Switch, Gauge and Sensor

Click Images to Enlarge

Three in one electronic pressure switch, digital pressure gauge and pressure sensor with pressure ranges from 100 mbar up to 600 bar (1.5 to 9000 psi) gauge or absolute.

Quote | PDF | Spec | Links

The DS 200 combined pressure switch, gauge and sensor is externally powered via the analogue signal electrical connection and pressure can be displayed in any engineering units via the 4 digit LED display.  A variety of analog output signals maybe specified and a choice of 1 or 2 PNP contacts for use as alarms or for controlling pumps and valves.

Special product features include a turndown ratio of 5 to 1 for the 3 wire 4-20mA output version for flexibility when stocking spares and an ATEX approved version of the 2 wire 4 to 20 mA output version for hazardous area applications.

 

Technical Summary

Pressure Ranges: 100 mb up to 600 bar (1.5 - 9000psi) gauge or absolute

Accuracy: ±0.175%Fs BSL standard with option for ±0.125%FS (analogue output)

Output Signals: 4-20mA 2 wire, 0-10V 3 wire and Adjustable 4-20mA 3 wire

Electrical Connections: DIN43650A plug & socket, M12 x 1 5 pin plastic or metal and cable gland

Pressure Connections: G1/2 and G1/4 DIN3852 or EN837, G1/2 and G3/4 DIN3852 flush, 1/2 and 1/4 NPT male

Display: 4 digit red LED, ±0.1% FS ± 1 digit accuracy plus analogue output accuracy

Switch Contacts: PNP, 125mA max for 4-20mA (2 or 3 wire) and 500mA max for 0-10V output.

Environmental Protection: IP65

Special Options: 5 to 1 rangeable, Ex approved intrinsic safety, all welded wetted parts


Related Products

Lower range combined pressure switch, gauge and sensor with ranges below 100 mbar

Battery powered digital pressure gauges

Plug-in LED display with switch output for DIN plug pressure transmitters

Alarm switch output panel meters


Resources

Glossary of pressure measurement technical terms

Guide to pressure units including converter and conversion factors


Download Product Information

DS200 data sheet DS200 data sheet

DS200 operating manual DS200 operating manual

Hazardous Area installation manual Hazardous Area installation manual


Request a Quote
Pressure Range:
Output Signal:
Accuracy:
Electrical Connection:
Length of Cable (metres) if required:
Pressure Connection:
Seals:
ATEX IS Approval (2 wire, 4-20mA and 1 switch only):
Switch Contacts:
Quantity:
Your Name:
Your Email:
Comments:

Home > Your Application > Intrinsically Safe > Absolute Pressure Transmitters for Hazardous Areas

Request Info | Ask a Question

Site Last Updated:  12/10/08

Tools
Pressure Conversion


Equals

Temperature Conversion


Equals

IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Resources

Pressure Measurement Glossary - Find explanations of terminology used for specifying and using pressure instruments

Pressure Unit Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Contact

Tel: +44 (0)1780 721569

Fax: +44 (0)1780 721586

Email: Enquiries

Help:  Request Info

         Ask a Question

News
RSS News Feed
RSS

©2008 SensorsONE Ltd, All Rights Reserved.