Economical IP68 protected sensor with stainless steel 316L housing and Ceramic strain gauge sensing diaphragm for measuring liquid depth pressure or the pressure in a submerged pipe or vessel. Measure hydrostatic pressure from from 0 to 10 mWC (33 ftWC) up to 0 to 100 mWC (330 ftWc) and convert reading to a millivolt, current or voltage signal output. The Ceramic diaphragm has a high chemical resistance to media such as leachate and seawater, and the housing can be upgraded to Duplex stainless steel if necessary for extra material protection. A PUR coated cable is fitted as standard, but for additional chemical protection an FEP coated cable can be supplied.
Product Parameters
Hydrostatic Level Ranges: 0-10 up to 0-100 mWG, 0-1.5 up to 0-10 bar absolute
Accuracy: 0.25% or 0.1% full scale BSL (11-12 bit resolution)
Output Signal: 4 to 20 mA current loop output and amplified voltage, mV/V uncompensated, 2mV/V ±1% rationalised, 10 mV/V ±1% rationalised and low amplification
Electrical Connection: Submersible integral cable with a PUR, PVC or FEP jacket.
Pressure Connection: 1/4 BSP male with protective nose cone
Media Compatibility: SS 316L, Duplex SS or PVC body, Ceramic Alumina Al2O3 diaphragm with NBR, Viton or EPDM O ring seals, PUR, PVC or FEP cable jacket
Diameter: 25 mm (1 inch)
Special Features: high corrosion resistant diaphragm
Special Options: Seawater use with Duplex stainless steel construction, chemically resistant plastic housing
Product Description
The IMCL low cost water proof liquid level sensor is designed for end user or OEM applications which require a low cost submersible sensor with a durable design and a medium grade accuracy performance. Threee different choices of housing, seals and cable are possible with the IMCL to provide 27 different configurations to suit a wide range of liquid media compatibility.
A high pressure water tight seal protects the signal conditioning electronics from leaking down to depths up to 100 metres (328 feet). The electronics are also protected from lightning induced voltage surges to reduce the risk of damage at exposed locations such as landfill sites and reservoirs.
The electrical signal of IMCL low cost IP68 hydrostatic level sensor can be a low power consumption millivolt output for connection to battery powered telemetry monitoring system or logging instrumentation. For process applications such as water treatment, landfill sites or tank storage a 4-20mA can be specified for transmitting a level reading from one side of a site to another through analogue signal cable wires.
Related Links
Seawater compatible pressure sensors
Plastic body hydrostatic level sensors
Download Product Information
Site Last Updated: 23/05/12
Glossary - Find explanations for terminology used in specifying and using pressure instruments
Pressure Conversion - Look up conversion factors or select a conversion table for a particular pressure unit
Pressure Measuring Guide - Collection of guidance notes for sourcing, setting up and using pressure measurement equipment
News Articles - Archive of application notes, product releases and technical information
Answers - Search for questions already answered or submit a new question about a pressure measurement topic or product
Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry
Product Finder - Choose multiple product and application types to filter out a suitable product
©2012 SensorsONE Ltd, all rights reserved.