LMK807 Plastic Submersible Level Transmitter

LMK807 Plastic Submersible Level Transmitter
KL1 Vented Cable Termination Enclosure

Click Images to Enlarge

IP68 mid range pressure transmitter for measuring the level of highly contaminated and agressive liquid media with a body made from PVC or PVDF. Hydrostatic ranges from 4 mWC up to 100 mWC

Price | Del | PDF | Links | Buy

 

Product Parameters

Hydrostatic Level Ranges: 4 to 100 mWC

Accuracy: 0.25% FS BSL NLHR

Output Signal: 4 to 20mA, 2 wire current loop

Electrical Connection: PVC, PUR or FEP cable with IP68 waterproof seal

Pressure Connection: Open face flush diaphram

Media Compatibility: PVC, PVDF or PVC-C sensor housing, FKM, EPDM or FFKM O ring seals and Ceramic Alumina Al2O3 diaphragm

Dimensions: 35 mm dia

Weight: 200 g

Special Features: Compatible with chemically corrosive fluids , no metal parts exposed to the liquid media

Special Options: Vented Aluminium cable termination box with over-voltage protection circuitry and/or internal PT 100 transmitter

 


Product Description 

The LMK 807 chemical resistant immersible level sensor includes a ceramic pressure sensing diaphragm which has a high corrosion resistant to most chemicals.

For waste-water applications the ceramic sensing element of the LMK-807 submersible level transmitter is semi-flush to prevent clogging and facilitate easy cleaning.

 


Delivery Time

3-4 weeks plus dispatch time

 


Related Products

Plastic immersible level transmitter with ranges below 4 mWC

More submersible hydrostatic level sensors

Flush diaphragm sensors for easy cleaning and decontamination

Liquid level transmitters with plastic wetted parts for corrosive chemicals

 


Resources

Condense choice of liquid level sensors by selecting application parameters

Scan this site for a level measurement topic or product

Meanings of specification parameters for pressure sensors

Metres of water column description and conversion factors

 


Download Product Information

LMK807 data sheet LMK807 data sheet

Cable Junction Box data sheet Cable Junction Box data sheet

LMK807 operating manual LMK807 operating manual


Quote/Buy

All prices are exclusive of any applicable VAT and delivery charges

£214.70

Hydrostatic Level Range:
Length and Type of Cable (metres):
Housing Material:
Seal Gasket Material:
Ceramic Diaphram Material:
Output Signal:
Vented Cable Junction Box:
Quantity:
Your Name:
Your Email:
Comments:
   

Home > Your Application > Sensor Technology > Ceramic Fluid Level Sensors > Plastic Body Ceramic Strain Gauge Level Sensors

Request Info | Ask a Question

Site Last Updated:  06/01/09

Tools
Pressure Conversion


Equals

Temperature Conversion


Equals

IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Resources

Pressure Measurement Glossary - Find explanations of terminology used for specifying and using pressure instruments

Pressure Unit Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Contact

Help:  Request Info

         Ask a Question

News
RSS News Feed
RSS

©2009 SensorsONE Ltd, All Rights Reserved.