Low range differential pressure sensor with rangeable 4-20mA current loop or amplified voltage output signal in pressure ranges from 1.6mb up to 6 bar differential
The DRS differential pressure transducer can be used with either non-condensing clean gases or low viscosity liquids & condensing dirty gases with the silicone oil filled option.
The digital electronics can easily be configured to set-up a turndown range of up to 5 to 1, compound range, elevated zero, square root output for flow measurement, customer specified non-linear output, filter jump out and RC time constant adjustment.
The DRS low differential pressure transmitter is designed for use in industrial, HVAC, laboratory, automotive test and process applications.
Technical Summary
Pressure Ranges: from 1.6 mb up to 6 bar differential
Accuracy: ±0.25% FS
Output Signal: Fully configurable 4 to 20 mA current or amplified voltage output available
Electrical Connection: Large DIN 43650 plug & socket, IP65 protection rating
Pressure Connection: 1/8 BSP female
Special Features: Rangeable turndown of 5 to 1 for each base range range
Special Options: Non-linear output signals, square root, 3/2, 5/2 type, high overload protection with XD (gas) and WS versions (liquids)