Baroli 05P High Range Flush Diaphragm Digital Pressure Gauge

High range pressure gauge for viscous fluids

Click Images to Enlarge

Battery powered pressure gauge with all welded wetted parts with exposed diaphragm for measuring high range pressures of viscous/pasty fluids or media which requires the use of hygienic equipment. Measure pressure ranges from 0-60 bar (900 psi) to 0-400 bar (6000 psi) gauge or absolute. Supplied with a G1/2 or a G1 male flush diaphragm process fitting for thread mounting.

Quote | PDF

 

Product Parameters

Pressure Ranges: 0-60 bar up to 0-400 bar gauge or absolute

Accuracy: +/-0.25% FS BSL

Display: 19999 digit LCD

Pressure Connections: 1/2 inch BSP flush or 1 inch BSP flush

Power Supply: 3.6V lithium battery type 1/2 AA (2 units)

Environmental Protection: IP65

Media Compatibility: Stainless steel 316L pressure port and diaphragm with FKM pressure seal

Weight: 350g minimum

Dimensions: 76.5mm diameter bezel, 129mm height

Special Features: Configurable Hi/Lo process warning indicator, 2 axis adjustment for display orientation, auto power saver

Special Options: Sanitary grade oil fill

 


Product Description

The Baroli 05P is designed for process and test measurements where the media is too thick and requires an open diaphragm to ensure the gauge is able to respond quickly to changes in pressure. 

If the process media is food, beverage, dairy or medical, a food grade oil which meets FDA requirements can be specified to protect the process from harmful contamination in the event of a diaphragm leak. 

The wetted parts are stainless steels 316L which has a low surface roughness and the non-corrosive properties required for production processes that require a high grade of cleanliness.

 


Related Products

Hygienic pressure sensors and gauges

Pressure gauges with digital readouts

Exposed diaphragm pressure measuring instruments

 


Download Product Information

Baroli 05P data sheet Baroli 05P data sheet


Request a Quote
Pressure Range:
Pressure Connection:
Oil Fill Fluid:
Calibration report, 5 points:
Quantity:
Name:
Email:
Country:
Comments:

Site Last Updated:  24/05/12

Save
Tools
Pressure Conversion



Converts to



Temperature Conversion



Converts to



IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Reference

Glossary - Find explanations for terminology used in specifying and using pressure instruments

Pressure Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Measuring Guide - Collection of guidance notes for sourcing, setting up and using pressure measurement equipment

News Articles - Archive of application notes, product releases and technical information

Answers - Search for questions already answered or submit a new question about a pressure measurement topic or product

Specify

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Product Finder - Choose multiple product and application types to filter out a suitable product

Articles


 

©2012 SensorsONE Ltd, all rights reserved.