KL1 Submersible Cable Termination Junction Box

Click Images to Enlarge

Robust cable junction box for terminating vented electrical cable from a 2 wire submersible hydrostatic level transmitter. The inside of the IP66 sealed box is vented to the ambient outside air via a PTFE filter to ensure the level sensor is properly vented to compensate for atmospheric pressure.

Quote | PDF | Spec | Links 

The KL1 enclosure is made from a die cast aluminium with a grey powder coating. The internal environment is sealed to IP66 to prevent dust or moisture ingress.  A PTFE filter pressure balance is incorporated into the enclosure wall to provide a vent path for the submersible sensor cable. 

Two M16 x 1.5 polyamide cable glands with NBR seals are fitted to the underside of the termination box to provide strain relief and an IP68 seal for the cable entry of the over-ground and submersible sensor cable.  The wires are terminated inside via vertical screw clamps which can accommodate wire with diameters up to 2.5mm2. 

In addition to providing a junction for a 2 wire 4-20mA output signal from a submersible borehole level sensor the KL1 termination box also has the options for including a PT100 transmitter and over-voltage discharge protection to 10 kiloamps related to nearby lightning strikes.

 

Technical Summary

Enclosure: IP66 sealed die cast Aluminium with grey powder coating

Cable Entry: M16 x 1.5 Polyamide cable gland with NBR seals

Electical Connections: screw clamps (wire < 2.5mm2) 

Dimensions: 125 x 80 x 58 mm

Weight: ~ 550 g

Special Options: Over voltage protection against discharges up to 10 kA, PT100 transmitter for an external temperature probe


Related Products

Submersible hydrostatic pressure transmitters

Level tape for gauging depth to water during installations


Resources

Convert hydrostatic pressure units

Glossary of pressure sensor terms


Download Product Information

KL1 data sheet KL1 data sheet

KL1 operating manual KL1 operating manual


Request a Quote
Cable Junction Box Type:
Quantity:
Your Name:
Your Email:
Comments:

Home > Your Industry > Geotechnical

Request Info | Ask a Question

Site Last Updated:  12/10/08

Tools
Pressure Conversion


Equals

Temperature Conversion


Equals

IP Ratings Explained

I P

First Digit (Solids)
No protection

Second Digit (Liquids)
No protection

Resources

Pressure Measurement Glossary - Find explanations of terminology used for specifying and using pressure instruments

Pressure Unit Conversion - Look up conversion factors or select a conversion table for a particular pressure unit

Pressure Sensor Specification - Select parameters with PSAT to generate a spec for your own use or to submit as an enquiry

Contact

Tel: +44 (0)1780 721569

Fax: +44 (0)1780 721586

Email: Enquiries

Help:  Request Info

         Ask a Question

News
RSS News Feed
RSS

©2008 SensorsONE Ltd, All Rights Reserved.