IP68 mid range pressure transmitter for measuring the level of highly contaminated and agressive liquid media with a body made from PVC or PVDF. Hydrostatic ranges from 4 mWC up to 100 mWC
For waste-water applications the ceramic sensing element of the LMK-807 submersible level transmitter is semi-flush to prevent clogging and facilitate easy cleaning.
Technical Summary
Hydrostatic Level Ranges: 4 to 100 mWC
Accuracy: 0.25% FS BSL NLHR
Output Signal: 4 to 20mA, 2 wire current loop
Electrical Connection: PVC, PUR or FEP cable with IP68 waterproof seal
Pressure Connection: Open face flush diaphram
Media Compatibility: PVC, PVDF or PVC-C sensor housing, FKM, EPDM or FFKM O ring seals and Ceramic Alumina Al2O3 diaphragm
Dimensions: 35 mm dia
Weight: 200 g
Special Features: Compatible with chemically corrosive fluids , no metal parts exposed to the liquid media
Special Options: Vented Aluminium cable termination box with over-voltage protection circuitry and/or internal PT 100 transmitter