TPF Flush Diaphragm Strain Gauge Pressure SensorFlush diaphragm piezo-resistive pressure sensor for food processing and plastic injection moulding applications with a millivolt output signal in pressure ranges from 10 up to 1000 barg.
Product Parameters Pressure Ranges: from 10 up to 1000 bar gauge Accuracy: 0.3% FS accuracy for ranges from 60 up to 1000 bar, 0.6% FS accuracy for ranges from 10 up to 50 bar Output Signals: 1.5 to 3 mv/V output sensitivity depending on pressure range. Electrical Connections: 6 pin military bayonet, DIN plug & Binder 7 pin with IP65, 66 or 67 protection ratings Pressure Connections: M18 x 1.5, 3/4-16 UNF, G1/2 male with flush diaphragm Special Features: R-Cal shunt calibration signal
Product Description The TPF flush mV output pressure sensor has an exposed stainless steel 17-4 PH diaphragm which has been developed for use with high viscosity fluids up to a temperature of +120 ºC.
Related Products 4-20mA, 5V or 10V output version of the TPF flush pressure sensor Panel meters for strain gauge pressure sensors Other types of flush diaphragm pressure sensors
Resources Benefits of using mV output pressure transducers Find an explanation for a pressure sensor term Convert a pressure range into bar units
Download Product Information